Laboratory
Through the Laboratory Management System , the laboratory ensures that its environment, equipment, personnel, etc., meet the requirements for laboratory capabilities, establishing the traceability of measurements to international units (SI Units).
Verification by TAF-accredited laboratories attests to the specific category of testing technical capabilities, allowing businesses to gain customer trust and ensure product quality.
International Bureau of weights & measures
01
National Measurement Laboratory
02
Testing & calibration laboratories
End Users
Manufacturing
Energy
National Defense
Environmental
Medical
Safety
Industrial Services
Technology
Legal Metrology
Trade
Reliability Testing Equipment

THERMAL SHOCK TESTER
Thermal Shock Time Range:
- H.TEMP:150℃ within 20 min
- L.TEMP:-50℃ within 45 min
Thermal shock testing range:
- 2 Zone rang:+120℃ ~ -50℃ within 3 min
- 3 Zone rang:+120℃ ~ RT ~ -50 within 3 min
Brand
T-MACHINE

RAIN TESTER
Ingress Protection:
- IPX5:Water Flow 12.5L/min
- IPX5:Water Flow 100 L/min
- IPX9K:Water Temp. 30~90°C
- Nozzle Distance 100~150 mm
- SAE:Spray Angle 45˚±5˚
- Water Flow 2.5+1.6-0 mm/min
- Platform Rotating Speed 4rpm
Brand
T-MACHINE

ZEISS COORDINATE MEASURING MACHINE
Optical ruler Resolution:
- 0.2 μm
Length Measurement Uncertainty:
- Equipment Accuracy MPEE = (0.9+L/350) μm
- Probe Accuracy MPE_THP = 1.3 μm
Brand
ZEISS

ANECHOIC BOX
Background Noise:
- Below 20 dB
Allowable Deviations:
- ≦ 630Hz → ±2.5 dB
- 800 to 5000Hz → ±2.0 dB
- ≧ 6300Hz → ±3.0 dB
Brand
_

TEMPERATURE & HUMIDITY CHAMBER
Temperature Range:
- 60℃ ~ 150℃
Humidity Range:
- 10%RH ~ 98%RH
Brand
T-MACHINE / KSON

GEARBOX AND MOTOR ELECTRICAL TESTER
Test Range:
- Torque Range:5 ~ 500 kgf.cm
- Speed Range:0 ~ 3000 rpm
Brand
_

KLINGELNBERG - PRECISION MEASURING CENTER
Module Range:
- Smallest / Largest Helix Angle:0°/ 90°
- Clamping Diameter:Max.160 mm
- Z Axis Measuring Range:250 mm
- X Axis Measuring Range:±50 mm
Machine Accuracy:
- Gear Measurement:VDI/VDE 2612 & 2613 Group I
- Shaft Measurement:U1=1.8 + L/250 μm
- Radial / Axial Runout Deviation:< 0.5 μm
Brand
KLINGELNBERG

STANDARD SALT SPRAY TESTER
Test Applicable:
- NSS、ACSS、CASS
- Test Temperature:35°C ± 1°C
- Quantity of Spray:1.5 ~ ±0.5 ml / hr
Brand
T-MACHINE

ATOS CAPSULE - PRECISION MEASURING MACHINE
- Probing Error Form:0.003 mm
- Probing Error Size:0.008 mm
- Sphere Spacing Error:0.009 mm
Brand
ZEISS

HOMMEL ROUGHNESS AND CONTOUR MEASUREMENT SYSTEM
- Roughness Resolution:0.001 µm
- Contour Resolution:0.1 µm
Brand
JENOPTIK

ENERGY DISPERSIVE X-ray FLUORESCENCE SPECTROMETER
Elements to Detected:
- 13Al ~ 92U
Brand
SHIMADZU

3D GAUSS TRACING SYSTEM
Measurement Points:
- 48000 Points / 360゜
Measurement range:
- 0 ~ 3000.0±5% mT
Model